Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Am J Trop Med Hyg ; 106(2): 562-565, 2022 01 07.
Article in English | MEDLINE | ID: covidwho-1614119

ABSTRACT

The dried-tube specimen (DTS) procedure was used to develop the COVID-19 serology control panel (CSCP). The DTS offers the benefit of shipping materials without a cold chain, allowing for greater access without deterioration of material integrity. Samples in the panel were sourced from COVID-19 convalescent persons from March to May 2020. The immunoglobulin subtypes (total Ig, IgM, and IgG) and their respective reactivity to severe acute respiratory syndrome coronavirus 2 nucleocapsid, spike, and receptor-binding domain antigens of the samples were delineated and compared with the WHO International Standard to elucidate the exact binding antibody units of each CSCP sample and ensure the CSCP provides adequate reactivity for different types of serological test platforms. We distribute the CSCP as a kit with five coded tubes to laboratories around the world to be used to compare test kits for external quality assurance, for harmonizing laboratory testing, and for use as training materials for laboratory workers.


Subject(s)
COVID-19 Serological Testing/methods , COVID-19/diagnosis , SARS-CoV-2/immunology , Specimen Handling/methods , Antibodies, Viral/blood , COVID-19 Serological Testing/standards , Coronavirus Nucleocapsid Proteins/immunology , Humans , Immunoglobulin G/blood , Immunoglobulin M/blood , Specimen Handling/standards , Spike Glycoprotein, Coronavirus/immunology , World Health Organization
2.
J Occup Environ Med ; 63(3): 191-198, 2021 03 01.
Article in English | MEDLINE | ID: covidwho-1307590

ABSTRACT

OBJECTIVES: Define the seroprevalence and risk factors for SARS-CoV-2 antibodies in Arapahoe County, Colorado first responders (eg, law enforcement, human services, fire departments). METHODS: Two hundred sixty four first responders were enrolled June to July 2020. SARS-CoV-2 seropositivity was defined as detection of immunoglobulin G (IgG) antibodies to both spike receptor binding domain and nucleocapsid in venous blood by validated enzyme-linked immunosorbent assay. We compared risk factors for being seropositive versus seronegative. RESULTS: 4% (11/264) were SARS-CoV-2 seropositive. Seropositive participants were significantly more likely to have lung disease (% seropositive, % seronegative; P-value) (36%, 8%; P = 0.01), prior SARS-CoV-2/COVID-19 testing (36%, 8%; P ≤ 0.01), a prior positive result (18%, less than 1%), and to believe they previously had COVID-19 (64%, 15%; P < 0.01). Only 15% of those believing they had COVID-19 had anti-SARS-CoV-2 antibodies. CONCLUSIONS: Human services employees and individuals with lung disease are at SARS-CoV-2 exposure risk. Few individuals believed they had COVID-19 had prior exposure.


Subject(s)
COVID-19/epidemiology , Emergency Responders/statistics & numerical data , SARS-CoV-2/immunology , Adult , Antibodies, Viral/blood , COVID-19/diagnosis , COVID-19/pathology , COVID-19/transmission , COVID-19 Serological Testing , Colorado/epidemiology , Female , Humans , Immunoglobulin G/blood , Male , Middle Aged , Risk Factors , SARS-CoV-2/isolation & purification , Seroepidemiologic Studies
3.
J Clin Microbiol ; 59(6)2021 05 19.
Article in English | MEDLINE | ID: covidwho-1255519

ABSTRACT

Serological testing of large representative populations for antibodies to SARS-CoV-2 is needed to estimate seroprevalence, transmission dynamics, and the duration of antibody responses from natural infection and vaccination. In this study, a high-throughput SARS-CoV-2 multiplex microsphere immunoassay (MMIA) was developed for the receptor binding domain (RBD) and nucleocapsid (N) that was more sensitive than enzyme-linked immunosorbent assay (ELISA) (98% versus 87%). The MMIA was then applied and validated in 264 first responders in Colorado using serum and dried blood spot (DBS) eluates, compared to ELISA, and evaluated for neutralizing antibodies. Four percent (11/264) of first responders were seropositive in July to August 2020. Serum and DBS were highly correlated for anti-RBD and anti-N antibodies (R = 0.83, P < 0.0001 and R = 0.87, P < 0.0001, respectively) by MMIA. The MMIA accurately predicted SARS-CoV-2 neutralizing antibodies using DBS (R = 0.76, P = 0.037). On repeat antibody testing 3 months later, anti-RBD IgG decreased less rapidly than anti-N IgG measured by MMIA, with a median change in geometric median fluorescence intensity of 62% versus 79% (P < 0.01) for anti-RBD and anti-N IgG, respectively. This novel MMIA using DBS could be scalable for rapid and affordable SARS-CoV-2 serosurveillance in the United States and globally.


Subject(s)
COVID-19 , Emergency Responders , Antibodies, Viral , COVID-19 Serological Testing , Colorado , Humans , Immunoassay , Microspheres , SARS-CoV-2 , Seroepidemiologic Studies
SELECTION OF CITATIONS
SEARCH DETAIL